banner



How To Connect Pelco Ip Camera To Netbotz Rack Monitor 570

APC NetBotz Room Monitor 570 (NBRK0570)

The APC NetBotz Room Monitor 570 (NBRK0570) offers premium security and environmental monitoring over the network. The NetBotz 570 is capable of video surveillance and monitoring to record whatsoever human activity. Information technology provides temperature, humidity, door contact, dry contact, 0-5V and 4-20mA sensor ports, vibration, fume, two-mode audio monitoring, spot leak, rope water leak, and warning beacon monitoring. Supports up to four external camera pods*, 12 sensor pods and up to 78 Universal Sensors - expands from 6 universal sensor ports on the appliance to upwardly to 78 with pod-based expansion. For management of multiple NetBotz appliances, utilise StruxureWare Data Centre Skilful.

  • Universal Sensor Ports: 6
  • Included Sensor: Temperature/Humidity (AP9335TH)
  • Optional Sensors: temperature, humidity, door contact, dry contact, 0-5V and 4-20mA sensor ports, vibration, smoke, 2-way audio monitoring, spot leak, rope water leak, and alarm beacon
  • Sensor Pods Supported (A-Link): 12, cascaded
  • Universal Sensors Supported: 78 via Pods
  • Photographic camera Support: 4 Networked or 4 USB*
  • Ability: 120-240V
  • Warranty: two years repair or replace

*Installing 4 camera pods requires an external USB hub.

Standard Lead Fourth dimension: Usually in Stock

APC NBRK0570 - Click to enlarge

APC
Cost: $3,755.00
At present: $2,517.24
Salve: $i,237.76

NBRK0570 Rear

Features

  • Environmental monitoring: Prevent equipment failure from a full range of threatening environmental weather.
  • Surveillance: Find and record motility, allowing a visual record to exist paired with an access or environmental alert, which speeds root cause analysis.
  • Fault notification: Real-time event notification minimizes response times to critical concrete infrastructure situations. Enables IT Administrators to reduce mean time to repair, improve efficiency, and maximize uptime.
  • Door Access monitoring: Find access by unauthorized personnel via door switch.
  • Browser Accessible: View the user interface with a browser. Provides quick access from anywhere on a secure network.
  • Adjustable threshold: Customize threshold definitions (multiple thresholds per sensor, scheduling, severity levels) to your requirements.
  • Customized escalation policies: Alerts are managed co-ordinate to your escalation policies and received in multiple formats.
  • Event-driven video storage: Video storage prompted past motility or alert.

Management

  • Browser Accessible: View the user interface with a browser. Provides quick access from anywhere on a secure network.
  • Enterprise management organization compatible: Make device information available to your preferred enterprise management system past forwarding SNMP traps (events) beyond SNMPv1, SNMPv2 and SNMPv3 using the PowerNet MIB
  • Integrates with StruxureWare Information Center Expert: For management of multiple NetBotz appliances, use StruxureWare Data Center Expert. StruxureWare Data Eye Expert surveillance licenses enable a single view of multiple cameras, rapid search and retrieval of video, plus 'tagging' of important video clips.
  • Advanced View client application: Robust apparatus interface provides historic alerts, graphs, and configuration.
  • Alerts View: Easily review and correlate alerts. Provide context to alerts by attaching video clips, graphs, and maps.

Sensors

  • half-dozen Sensor Ports for connecting temperature, humidity, fume, door, vibration, spot fluid, and third-party dry contact and 0�5 V sensors.
  • Third-party dry out contact sensors crave the NetBotz Dry out Contact Cable (NBES0304). To connect a sensor to the cablevision, follow the instructions provided with the sensor and the instructions provided with the cablevision.
  • Standard third-party 0-v 5 sensors require the NetBotz 0-5 Five Sensor Cablevision (NBES0305). To connect a sensor to the cablevision, follow the instructions provided with the sensor and the instructions provided with the cable.
  • Sensor Pods (A-Link): Y'all can cascade up to a combined total of twelve NetBotz Rack Sensor Pod 150s (NBPD0150), NetBotz Room Sensor Pod 155s (NBPD0155), and NetBotz Rack Access Pod 170s (NBPD0171, NBPD0172) and up to a combined total of eight Temperature Sensors with Digital Display (AP9520T) and Temperature/ Humidity Sensors with Digital Display (AP9520TH).

NBRK0570 Includes

  • NetBotz Room Monitor 570
  • Brackets for a standard 19-in rack
  • M4 x viii Phillips flat-caput screws
  • Power cord retainer bracket
  • eight-position concluding block plug
  • 9-position terminal block plug
  • 203-mm (8-in) necktie wraps
  • NetBotz Appliance Utility CD
  • 203-mm (8-in) hook and loop cable strap
  • i.8-grand (6-ft) IEC-320-C13 to IEC-320-C14 power cord
  • 1.8-m (vi-ft) NEMA 5-15P to IEC-320-C13 ability cord
  • 5-m (16.four-ft) USB cable
  • 3-position concluding block plug
  • Temperature/Humidity Sensor (AP9335TH)

Download IconAPC NetBotz 570 Installation & Configuration Manual (PDF)

NetBotz 570 (NBRK0570) Specifications

Physical Characteristics
Top i.71 in. (43mm.)
Width 17.00 in. (432mm.)
Depth 3.66 in. (93mm.)
Net Weight 3.83 lbs (1.74 kg)
Mountain Position 1U Rackmount
Environmental
Storage Temperature 5 - 149 �F (-fifteen - 65 �C)
Operating Temperature 32 - 113 �F (0 - 45 �C)
Storage Humidity 10 - 95%
Operating Humidity 10 - 95%
Storage Elevation 0-50000 feet (0-15000 meters)
Operation Superlative 0-10000 feet (0-3000 meters)
Ability AC 120-240V V @ 50/lx Hz - Internal Power Supply
Power Cords - ane.8-thou (6-ft) IEC-320-C13 to IEC-320-C14 power cord
- 1.viii-m (half dozen-ft) NEMA five-15P to IEC-320-C13 power string
Connectors, Sensors & Cameras
Connectors Ethernet: (ane) 10/100 Base of operations-T Ethernet Port
Power: Air conditioning Line Inlet Port 100-240 V AC, l/sixty Hz
(half-dozen) APC Universal Sensor Ports
(one) USB Configuration Port � Style B
(4) USB Ports � Mode A
(1) A-Link Port
(1) Voltage Output Port
(2) Relay Output Ports
(4) iv-20mA Input Ports
(1) Buoy Port
(1) Rope Leak Sensor Port
(1) RS-485 Modbus connection
External Cameras Supported NetBotz Photographic camera Pod 160; Pelco IP Camera Families: Sarix, Spectra Four IP, Spectra Mini IP (Pelco IP110-CHV9, Pelco IP3701H-2, Pelco IPSD4N-W0); NTSC, PAL; IP110 Camclosure; IP3701; and CCTV Cameras integrated through the NetBotz CCTV Adapter Pod
APC Universal Sensors Supported Temperature; Temperature / Humidity; Door Contact; Smoke; Spot Leak; Vibration; Dry Contact; 0-5V; 4-20mA
Sensors and Pods Supported iv - 20mA Sensor, Camera Pod 120, CCTV Adapter Pod 120, Rack Sensor Pod 150, Room Sensor Pod 155, Sensor Pod 120, Wireless Sensor Pod 180
Communications & Management
Protocols TCP/IP; HTTP; HTTPS; SMTP; SNMP v1, v2c, and v3; DHCP; DNS; Socks v4 or V5 Proxy Server; A-Link
Network Interface Connections RJ-45 10/100 Base-T
Direction Interface Internet Explorer v 5.5 or afterwards; Mozilla 1.iii or later on; Firefox 2.0 or after; NetBotz Advanced View Software; StruxureWare Data Center Expert
Client System Requirements Microsoft Windows seven Pro and Ultimate; Vista Business and Enterprise; XP SP2-3; Ruby-red Hat EL4 and EL5 Employ of Advanced View interface requires a one-time download of the Sun Java Runtime Environs
Indicators Alert; Ability; Network Link
Approvals CE; UL; c-UL; VDE; IRAM; NOM; GOST; FCC 47 CFR Part fifteen Class A; ICES-003 Class A; AS/NZS CISPR 22; VCCI Form A; Low Voltage Directive 2006/95/EC; EMC Directive 2004/108/EC
Warranty 2 years repair or replace
APC Temperature Sensor with Display (A-Link)
$184.15
APC Temperature Sensor with Brandish (A-Link)
APC AP9520T NetBotz is a A-Link Sensor that monitors temperature in your Data Eye or Network Closet. Display provides visual reporting of temperature levels. Compatible with select NetBotz appliances
NetBotz Spot Fluid Sensor - 15 ft.
$122.62
NetBotz Spot Fluid Sensor - 15 ft.
APC NBES0301 NetBotz 15 Ft universal Sensor that provides early detection of fluid in your Information Heart or Network Closet in a specified location.
NetBotz Leak Rope Sensor - 20 ft.
$308.05
NetBotz Leak Rope Sensor - xx ft.
20 ft Leak Rope Sensor provides early on detection of fluid in your information center or network cupboard along the entire length. Compatible with select NetBotz appliances (Rack Monitor 455, Room Monitor 570).
NetBotz Leak Rope Extension - 20 ft.
$242.53
NetBotz Leak Rope Extension - xx ft.
Extend the length of your rope leak sensor by 20 ft to ensure proper leak detection coverage in your data centre or network closet. Requires NBES0308.
NetBotz Dry Contact Cable - 15 ft - For 3rd Party Sensors
$58.00
NetBotz Dry Contact Cable - 15 ft - For tertiary Party Sensors
APC NBES0304 NetBotz is a 15ft universal Sensor that monitors third-party dry contact land sensors. With this cable you can now use many standard dry contact�based sensors (such as motion detectors, moisture detectors, or drinking glass-break detectors) as external NetBotz sensors.
APC Alarm Beacon
$179.31
APC Alarm Beacon
Apace notify personnel of critical situations with a visible warning signal.
APC NetBotz 4-20mA Sensor Pod - Monitor 4 x Analog Sensors.
$325.58
APC NetBotz 4-20mA Sensor Pod - Monitor 4 x Analog Sensors.
APC NetBotz four-20mA Sensor Pod (NBPD0129) enables you lot to connect up to four 4-20mA sensors to your NetBotz 455or NetBotz 500 appliance. Hundreds of four-20mA sensors are available from third-parties, including sensors designed to measure liquid flow rates, liquid levels, gases, pressure, temperature, air velocity, voltage, and more.
NetBotz Rack Sensor Pod 150
$296.55
NetBotz Rack Sensor Pod 150
APC NetBotz Rack Sensor Pod 150 (NBPD0150) connects to a NetBotz appliance and allows y'all to increase the space monitored past your NetBotz security and environmental monitoring system. The NetBotz 150 includes six sensor ports for monitoring input from APC environmental sensors and other third-party sensors.
NetBotz Room Sensor Pod 155
$348.28
NetBotz Room Sensor Pod 155
APC NetBotz Room Sensor Pod 155 (NBPD0155) connects to a NetBotz appliance and allows you to increment the space monitored by your NetBotz security and environmental monitoring system. The NetBotz 155 includes iv sensor ports for connecting APC environmental sensors and other third-party sensors. The NetBotz 155 besides includes built-in temperature, humidity, and airflow sensors
NetBotz Wireless Sensor Pod 180
$279.99
NetBotz Wireless Sensor Pod 180
Wireless Sensor Pod 180 (NBPD0180) connects to a NetBotz apparatus and allows yous to monitor the temperature and humidity (internal sensors included) in a rack in your information middle. The Wireless Sensor Pod includes three Universal Sensor ports, and upwards to 48 Wireless sensors for connecting additional sensors that let you lot to monitor rack door access, and multiple temperature readings for the rack.

Question: how much power does a 570 describe?
Answer: Thanks for your research. The max total current draw for the NBRK0570 is 2 Amps.